Plywood Thickness Guide — Which Thickness for Subfloor, Roof, Walls & Shelving
This guide answers one question: which thickness family fits the job you are doing. Pick a scenario below for a reference range, the spacing rule behind it and the calculator that finishes the estimate.
Application selector
A reference lookup only. It does not calculate sheet counts, output project costs or certify a structural specification.
Joist spacing, panel span rating and whether the floor is a single or double layer decide the accepted panel. Common framing module; 5/8" or 3/4" products appear often, subject to the span rating.
Important. This page is an initial reference, not a substitute for professional design, the panel's published span rating, the current code edition in your jurisdiction or the manufacturer's instructions. Structural parameters are shown as ranges and inputs for you to verify; no single thickness is certified as safe for your project.
Plywood Thickness by Application
Start here for the fast answer. Each row pairs a typical nominal range with the variable that actually decides the panel. “Check the specific product data sheet” is deliberate: thickness ranges are useful for planning, but span ratings and structural grades are product properties.
| Application | Common Nominal Thickness | Actual Thickness Reference | Spacing / Selection Basis | Related Calculator |
|---|---|---|---|---|
| Subfloor | 5/8"–3/4" | Check the specific product data sheet | Joist spacing, span rating and the floor system together decide the panel. | Subfloor calculator |
| Roof Sheathing | 7/16"–5/8" | Check the specific product data sheet | Rafter spacing, panel span rating and edge support requirements. | Roof sheathing calculator |
| Wall Sheathing | 3/8"–1/2" | Check the specific product data sheet | Stud spacing, structural grade and wall design requirements. | Wall sheathing calculator |
| Shed Floor | 5/8"–3/4" | By joist spacing, span and load | Light-structure floor selection; do not assume a residential subfloor specification transfers. | Subfloor calculator |
| Attic Storage Flooring | By joist spacing and load | Do not treat ordinary ceiling joists as storage-floor support | Verify the framing was designed for storage loading before choosing a panel. | Span calculator |
| Garage Shelving | 1/2"–3/4" | By shelf span, depth and load | Heavy shelves need a stiffness check as well as a thickness choice. | Span calculator |
| Cabinet Panels | 1/2"–3/4" | By part size and load requirement | Furniture panel selection by component rather than by one sheet thickness. | Cabinet calculator |
| Boat / Camper / Trailer Flooring | By substrate, moisture and load | Must follow the actual structure and manufacturer advice | No universal structural-safety thickness is offered for mobile applications. | Span calculator |
Source basis: APA Panel Design Specification and Rated Sheathing product data, plus the applicable IRC editions for floor, roof and wall sheathing. Verify the current version, panel grade, span rating and local amendments before treating any row as a requirement.
Floor systems: subfloor, underlayment and finished floor
The words describe three different layers, and confusing them is the fastest way to buy the wrong sheet. The subfloor is the structural panel fastened to the joists. Underlayment is a thinner layer added above it to smooth the surface for a finish material. The finished floor is what you walk on. A subfloor decision starts with joist spacing and the panel span rating stamped on the sheet, not with the thickness of the flooring you plan to install.
Tongue-and-groove edges help adjacent panels share load across a joint, which is why the T&G edge should land on support. Glue and fastener spacing are part of the system: a panel screw schedules edge and field positions differently because edges carry more load per fastener. If you need the count rather than the selection rule, the subfloor calculator converts your room dimensions, spacing and waste allowance into sheets.
Subfloor thickness by joist spacing
The table below is a decision aid, not a code table. Spacing narrows the choice; the stamped span rating and the floor assembly close it. Never convert a 16-inch-OC selection into a 19.2-inch-OC specification by rounding.
| Joist Spacing | Common Panel Selection | Selection Notes |
|---|---|---|
| 12" OC | Select by the APA span rating on the panel | Do not assign a thickness from spacing alone. |
| 16" OC | Commonly 5/8" or 3/4" products | Check the span rating and whether the floor is single-layer or double-layer. |
| 19.2" OC | Follow the product's marked span rating | Do not carry over a 16-inch-OC specification. |
| 24" OC | Typically a higher grade or thicker panel | Verify against the manufacturer's tables and the applicable code edition. |
Roof systems: rafter spacing, span rating and edge support
Roof sheathing is commonly 7/16 to 5/8 inch, but the label is only the start. Rafter spacing decides how far a panel must span between supports; the panel span rating tells you what the manufacturer certified that panel for; edge support — blocking, clips or a continuous edge — decides whether an unsupported joint can be relied on. Skip any one of the three and a thickness table becomes a guess.
Roof pitch changes the area you cover but not the structural requirement between supports, which is why the roof sheathing calculator takes pitch and roof type for quantities while this guide stays with selection. Local requirements can be stricter than a generic range, particularly in high-wind or heavy-snow areas. Verify the current code edition and the panel stamp together.
Roof and wall sheathing selection
| Application | Framing Spacing | Selection Considerations |
|---|---|---|
| Roof Sheathing | 16" OC / 24" OC | Combine rafter spacing, panel span rating, edge support and local requirements. |
| Wall Sheathing | 16" OC / 24" OC | Combine stud spacing, structural grade, shear-wall design and fastening requirements. |
Wall systems: structural sheathing vs decorative paneling
Wall sheathing at 3/8 to 1/2 inch is chosen for stud spacing, structural grade and the wall's resistance to racking. In a shear wall the panel is part of the lateral system and its fastening schedule is as important as its thickness. Interior paneling, by contrast, is selected for appearance and mounting method; it can be thinner and need no structural rating. The two uses share a material name but not a specification, and substituting decorative paneling for sheathing removes a structural function from the wall.
Exterior walls add moisture management to the decision. Exposure-rated bond, sealant at penetrations and the cladding system all interact with the sheathing. This page stops at the plywood choice; a full wall assembly belongs in the building design, not in a thickness lookup.
Light structures: shed floors, attic storage and garage shelving
Shed floors commonly use 5/8 to 3/4 inch panels, but a shed is its own structure: joist size, unsupported span and the intended load decide the sheet just as they do in a house. Treating a residential subfloor thickness as automatic is a common mistake because the shed may use wider spacing or lighter framing.
Attic storage is the most frequently misjudged case in this guide. Ceiling joists are often sized for a ceiling, not for stored boxes and a person walking among them. Before choosing any panel, confirm the framing was designed for that load. Garage shelving is simpler but still needs a span check: a 1/2-inch shelf at 24 inches between supports behaves very differently from the same shelf at 48 inches. Use the span calculator for both cases.
Mobile applications: boat, camper and trailer flooring
In a boat, camper or trailer the plywood floor is part of a vehicle assembly. The underframe, the way the panel is bonded or fastened, repeated vibration and sustained moisture exposure all matter more than a generic thickness number. Manufacturers specify the panel as part of the structure, and replacing it with a different thickness changes weight, height and load paths.
For that reason this guide does not publish a universal “safe” thickness for mobile flooring. Use the span calculator to explore how your proposed panel and support spacing behave, then compare the result with the manufacturer's documented assembly. A thickness lookup cannot substitute for a vehicle-specific specification.
Special applications: mobile home, bathroom, tile and climbing walls
Mobile home floors are manufactured assemblies; repairs should match the original specification rather than a generic table. Bathroom floors add water exposure and usually a surface finish that dictates its own underlayment. Tile needs a substrate approved for the tile system, with movement and moisture requirements that a plywood thickness alone cannot satisfy. Shiplap is a decorative profile with its own fastening and gap rules.
A climbing wall is a load-bearing structure. It needs an engineered design, defined anchor points and a qualified review; selecting 3/4 inch plywood from a table is not a structural decision. These cases are listed here so the boundary of this guide is explicit: where the system dominates, the thickness chart hands off rather than pretending to answer.
If you came here for what thickness plywood for subfloor, roof, walls and shelving, the selector above is the short answer. The full reasoning lives in our homepage calculator walkthrough and in the guides library, where this guide sits beside actual-thickness and sheet-size references.
Keep thickness and selection separate
This guide deliberately does not repeat the nominal-versus-actual table. If you know the thickness you need but want to know what the label measures — including the common 23/32 and 19/32 values — open the plywood thickness chart. The two pages divide the work: that one converts a name into a dimension, this one converts a scenario into a range. Keeping them separate prevents a lookup table from being mistaken for a structural recommendation.
Related references
- Subfloor calculatorTurn a chosen subfloor panel into a room-by-room sheet count.
- Roof sheathing calculatorPitch, waste and thickness by rafter spacing.
- Wall sheathing calculatorOpenings, stud spacing and net wall area in one pass.
- Span calculatorCheck deflection and load for shelves, floors and light structures.
- Plywood thickness chartNominal labels mapped to actual fractions, decimals and millimetres.
Questions by application
What thickness plywood should I use for a subfloor?▼
The common range is 5/8" to 3/4", with 23/32" actual often used for living areas. The accepted panel depends on joist spacing, the APA span rating stamped on the sheet and whether the design uses one layer or two. Check all three before buying.
What size plywood for a bathroom floor?▼
Bathroom floors add moisture exposure and often a tile or stone finish, so the substrate and underlayment system matter as much as thickness. Follow the floor manufacturer's assembly requirements and the span rating for your joist spacing rather than assuming a generic thickness is sufficient.
What size plywood for a shed floor or shed roof?▼
Shed floors commonly use 5/8"–3/4" panels and shed roofs 7/16"–5/8", but the real inputs are joist or rafter spacing, unsupported span and the local load conditions. A light structure does not inherit the specification of a residential floor or roof.
What size plywood for a mobile home, camper or trailer floor?▼
These floors depend on the vehicle's own underframe, moisture environment and loading, and manufacturers specify the panel as part of the assembly. No single plywood thickness is safe to recommend in isolation; consult the manufacturer's documentation.
What thickness plywood for a roof?▼
Roof sheathing is commonly 7/16" to 5/8", selected by rafter spacing, the panel span rating and edge support. Check the stamp and the current code edition for your jurisdiction; a thicker sheet is not automatically the right sheet.
What size plywood for walls and exterior walls?▼
Wall sheathing commonly falls between 3/8" and 1/2", chosen by stud spacing, structural grade and shear-wall design. Interior decorative paneling is a different product decision from structural sheathing and should not be substituted for it.
What thickness plywood should I use for shelves?▼
Garage and utility shelves often start around 1/2" to 3/4", but the deciding factors are shelf span, depth and load. A long heavily loaded shelf needs a deflection check; nominal thickness alone does not guarantee stiffness.
What size plywood for tile, shiplap or a climbing wall?▼
Tile needs a substrate and underlayment assembly approved for the tile system; shiplap is a decorative profile with its own installation rules; a climbing wall is a load-bearing structure that needs engineered design. None of these reduce to one plywood thickness.
¿Qué grosor de plywood para piso? (what thickness for floor)▼
Para pisos, el rango habitual es 5/8" a 3/4" (15.1–18.3 mm), pero la decisión depende del espaciado de viguetas y la clasificación de luz del panel. Consulte la ficha del producto y el código local antes de comprar.
What thickness plywood for an attic floor?▼
Only choose a panel after confirming the joists were designed to carry storage loads. Ordinary ceiling joists may not qualify. Once the structure is verified, use the span calculator with your joist spacing and intended load.
Does this guide tell me how many sheets to buy?▼
No. This guide selects a thickness family for an application. Sheet counts and costs belong to the paired calculators: subfloor, roof sheathing, wall sheathing, cabinet and span tools each take your dimensions and return quantities or structural checks.
Where do I find the actual thickness behind these names?▼
Use the plywood thickness chart linked on this page. That page converts nominal labels such as 3/4 and 5/8 into the commonly published actual dimensions in fractions, decimals and millimeters, without making an application recommendation.
Written and reviewed by the Plywood Calculator editorial team. Last updated 23 November 2026. Ranges checked against APA Panel Design Specification, APA Rated Sheathing data and applicable IRC editions; verify the current version and your local requirements.